MAX 9000 Dedicated Inputs
- 2 Dedicated Global Clock Inputs Can Drive:
- Any Macrocell Control Signal (Clock, Clear, Preset, Enable)
- Clock Signals on Peripheral Control Bus*
- Data
- Any Combination of Above (Non-Global Signal Use May Result)**
- 1 Dedicated Global Clear Input Can Drive:
- Any Macrocell Control Signal (Clock, Clear, Preset, Enable)
- Clear and Clock Enable Signals on Peripheral Control Bus*
- Data
- Any Combination of Above (Non-Global Signal Use May Result)**
- 1 Dedicated Global OE Input Can Drive:
- Any Macrocell Control Signal (Clock, Clear, Preset, Enable)
- Output Enable, Clock Enable, and Clear Signals on Peripheral Control Bus*
- Data
- Any Combination of Above (Non-Global Signal Use May Result)**
* Peripheral control bus signals drive I/O Cells (IOCs)
** Data loading on non-global signals will add delay