Device Timing: Clock-to-Out
- Register Clock-to-Q Time (See Data Book)
- Clock Delay Depends on Resource Used
- Dedicated Inputs Drive Global Nets
- I/O Pins Drive Row & Column Interconnects
- Data Delay Factors
- Proximity of Output Pin & Register
- IOE Register always provides fastest clock-to-output (FLEX 8000)
tCO = Clock Delay + Register Clock-to-Q Time + Data Delay